产品名称: |
岛津Porapak Q甲烷柱 |
产品型号: |
|
品牌: |
1941 |
产品数量: |
|
产品单价: |
面议 |
日期: |
2022-01-10 |
岛津Porapak Q甲烷柱的详细资料
岛津Porapak Q甲烷柱
岛津Porapak Q甲烷柱 详细信息:
名称:甲烷柱
固定相:高分子小球
粒度:60-80目
型号:PQ
规格:2m*1/8
应用:环境空气/固定污染源废气/甲烷,总烃,非甲烷总烃的测定
适用于:安捷伦,赛默飞,瓦里安,布鲁克,PE,岛津
随着经济社会的发展,不断扩大的工业生产向空气中排放着大量污染物,这就需要准确的检测数据以实现有效的环境管理.气相色谱法检测废气中的甲烷,非甲烷总烃,应用甲烷作为标准参考气体较为合适,与丙烷比较,对非甲烷总烃的定量没有较大差别,且时间上明显缩短,提升了作业效率;在仪器配置上,浩瀚色谱(山东)应用技术开发有限公司建议采用双柱配置的气相色谱,一次进样做完所有分析,效率更高,而且能够有效提高实验结果的准确性;手工配制方法尽管有些麻烦,但也能较好的满足实验要求,且成本更低;与
毛细管柱相比来说,
填充柱的检出限尽管稍差,但成本更低,已经能够满足实验要求;在样品采集环节,污染源具有负压时,需要选用动力采样,而其余情况以及无组织排放,采用玻璃注射器采集,再注入惰性气袋存放即可,这样不但提高了采集效率,而且更加方便运送,气密性也很好,方便保存.
岛津Porapak Q甲烷柱 测试谱图:














Shimadzu Porapak Q methane column
Shimadzu Porapak Q methane column Details:
Name: Methane column
Statio
nary phase: polymer beads
Granularity: 60-80 mesh
Model: PQ
Specifications: 2m*1/8
Application: Determination of ambient air/statio
nary pollution source waste gas/methane, total hydrocarbons, non-methane total hydrocarbons
Available for: Agilent, Thermo Fisher, Varian, Bruker, PE, Shimadzu
With the development of eco
nomy and society, the expanding industrial production emits a large amount of pollutants into the air, which requires accurate detection data to achieve effective enviro
nmental management. Gas chromatography is used to detect methane and non-methane total hydrocarbons in exhaust gas. Methane is more suitable as a standard reference gas. Compared with propane, there is no significant difference in the quantification of non-methane total hydrocarbons, and the time is significantly shortened, which improves the operation efficiency; in terms of instrument configuration, Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. It is recommended to use a gas chromatograph with a dual-column co
nfiguration to complete all analyses in one injection, which is more efficient and can effectively improve the accuracy of the experimental results; although the manual preparation method is somewhat troublesome, it can also better meet the experimental requirements, and the cost Compared with the capillary column, the detection limit of the packed column is slightly worse, but the cost is lower, and it can already meet the experimental requirements; in the sample collection process, when the pollution source has negative pressure, it is necessary to use dynamic sampling, while the other It can not o
nly improve the collection efficiency, but also more co
nvenient for transportation, and the air tightness is also very good, which is co
nvenient for storage.
Shimadzu Porapak Q methane column test spectrum: